Hazardous / Flammable liquids in Chemical, Fertilizer, Petrochemical, Pharma, Pesticide and other industries like:
-> Liquefied Gases: LPG, Cl2, NH3, C4 cut, aHF
-> Corrosives:H2SO4, Oleum 65%, HNO3, HCl, Acetic Acid, PCl3 etc.
-> Petrochemicals:Ethylene, EO, ACN, VC, EDC, Butadiene & Solvents
-> Oils: Veg. Oils, Fatty Acids, Fuels, Thermic fluids, lube oils, etc
-> Others:Pesticides, H2SiF6, Silicates, Brine, Alkalies, Freons,etc
A float containing magnets, moves up & down with changing liquid level, in a non-magnetic - non-fragile chamber.
“Indicap follower” or “Bicoloured Rotocyls” indicate level externally. The “Indicap Follower” moves within a glass tube filled with water. Water makes the capsule weightless and reduces friction. The indication is continuous.
The “Bi-coloured Rotocyl” system comprises of series of bicoloured cylinders that hold each other by tiny magnets within. As the strong magnet of the float moves behind them, they turn inside out. Level is indicated as rising bar of yellow. In contrast empty space above is seen as black. Resolution limited by Rotocyl width
MOC: CS, SS, PP, PVDF
Operational Pressures: Abs. Vacuum to 30 Bar
Operational Tempreture:-50o to 300oC
Range:300-6000 mm:
Ultimate Safety: No glass breakage, no gland leakage. The non-fragile chamber of metal or plastic eliminates messy and hazardous spills.
Excellent Visibility: Designed for colourless, transparent or even tarry black liquid. Indication is clearly visible from over 30 meters
Simple, Economical & Maintenance Free: : In reflex transparent Gauges, the number of joints, glasses, nut bolts, valves and other parts call for cumbersome maintenance and involve high investment and running cost. In contrast, Magnetic Indicators are maintenance-free and hence very economical
Note:
* marked details are essential for ordering
Specifications in () Brackets are available on specific request
Construction | Metallic | Plastic |
---|---|---|
MOUNTING | Side of the Tank | Side of the Tank |
MATERIAL | ||
MoC wetted * | Stainless Steel 304, 316, 304 L, 316 L | PP, PVDF, PTFE |
Flanges | CS, SS304, SS316, SS304 L, SS316 L | PP lined IS-2062, PVDF, PTFE lined IS-2062 |
Chamber | A312 TP SS | PP, PVDF, PTFE lined SS304 |
Float | SS316L or ECTFE coated SS316L | PP, PVDF, ECTFE coated SS316L |
Guard | SS304 | SS304 |
Scale | Aluminium ( SS304, Acrylic, PVC) | Aluminium ( SS304, Acrylic, PVC) |
Gasket | CAF (PTFE, Graphoil) | PTFE |
Nut Bolts | CS (SS304, ASTM A193 Gr b7/ A194 Gr 2h) | CS (SS304, ASTM A193 Gr b7/ A194 Gr 2h) |
Paint | Enamel –Phiroza blue, (Epoxy –White) | Enamel –Phiroza blue, (Epoxy –White) |
CONNECTION | ||
*Process | Flanged-SORF(WNRF,T&G) (Threaded:NPT/BSP); 25 NB (15 NB to 50 NB); ANSI B16.5 #150, (300, 600);(BS 10: Table D/E/F) (DIN PN10/16/32) | Flanged SORF; 25 NB (40, 50 NB); ANSI B16.5 #150; (BS 10: Table D/E/F) (DIN PN10 or 16) |
Drain & Vent | ½” NPT Plug ( ½” Ball/Needle Valve, Flange) | 25 NB ANSI B16.5 # 150 Flange (Ball Valve) |
OTHER | ||
Indication* | Indicap: Red follower Capsule (Rotocyl) | Indicap: Red follower Capsule (Rotocyl) |
Centre to Centre Distance* | 300 to 5500 mm | 300 to 4500 mm |
Float Diameter | 50 mm to 86 mm | 50 mm to 90 mm |
Chamber O.D | 64 mm to 110 mm | 90 mm to 110 m |
Sp.Gr.* | min 1.0 (low up to 0.45) | min 1.0 (low up to 0.45) |
Temperature* | -50 to 150º C | PP: -50 to 100º C PVDF & PTFE: -50 to 150º C |
Hydro Test* | 5 bar (chamber: 60 bar max, Float: 32 bar max.) | Atm |
Vacuum | Full Vacuum | Full Vacuum |
Least count | 5 mm | 5 mm |
Accuracy | ±1 cms (For Sp.Gr. = 1) | ±1 cms (For Sp.Gr. = 1) |
OPTIONS | ||
Mounting | Side-Top, Side-Bottom | Side-Top, Side-Bottom |
Switch | Micro, Potential Free contact, 5 A 230VAC SPDT; Die cast Al.-LM6 Enclosure, Weather Proof IP65; (Flameproof IS2148 Gr IIa, IIb or IIc) | Micro, Potential Free contact, 5 A 230VAC SPDT; Die cast Al.-LM6 Enclosure, Weather Proof IP65; (Flameproof IS2148 Gr IIa, IIb or IIc) |
Transmitter | Intrinsically Safe transmitter with 4-20 mA out put (HART®) | Intrinsically Safe transmitter with 4-20 mA out put (HART®) |
Heating Manifold | Grid of SS304 tubes with ½” NPT(F) inlet / outlet | - |
Construction | Metallic | Plastic |
---|---|---|
MOUNTING | Top of the Tank | Top of the Tank |
MATERIAL | ||
MoC wetted * | C.S. Stainless Steel SS304, SS316, SS304 L, SS316 L | PP, PVDF |
Flanges | CS, SS304, SS316, SS304 L, SS316 L | PP lined IS-2062, PVDF, PTFE lined IS-2062 |
Top Chamber | A312 TP SS | PP, PVDF |
Flanges | CS, SS304, SS316, SS304 L, SS316 L | PP lined IS-2062, PVDF, PTFE lined IS-2062 |
Guide Pipe(Cage) | CS, SS304, SS304L, SS316, SS316L( Cage for interface / slurry application) | PP, PVDF |
Float | SS316L (ECTFE coated SS316L) | PP, PVDF, (Glass, ECTFE coated SS316L) |
Guard | SS304 | PP, PVDF, (Glass, ECTFE coated SS316L) |
Scale | Aluminium ( SS304, Acrylic, PVC) | Aluminium ( SS304, Acrylic, PVC) |
Gaskets, Nut Bolts | Buyer’s Scope | Buyer’s Scope |
Paint | Enamel –Phiroza blue, (Epoxy –White) | Enamel –Phiroza blue, (Epoxy –White) |
PROCESS CONNECTIONS | ||
Types* | Flanged-SORF (Small / Large T & G) | Flanged SORF |
Size* | 100 NB (150, 200 NB) | 100 NB (150, 200 NB) |
Flange std* | ANSI B16.5 # 150 ,(300, 600)(BS 10 : Table D / E / F) (DIN: PN 10, PN 16 , PN 32.) | ANSI B16.5 # 150(BS 10: Table D/ E /F, DIN PN10 or 16) |
OTHER | ||
Indication* | Indicap: Red follower Capsule (Rotocyl) | Indicap: Red follower Capsule (Rotocyl) |
Centre to Centre Distance* | 500 to 3000 mm in single stage, 500 to 6000 mm in double stage | 500 to 3000 mm, 500 to 4500 mm in double stage |
Float Diameter | 70 mm to 110 mm | 50 mm to 90 mm |
Guided Pipe O.D | 64 mm to 140 mm | 75 mm to 100 mm |
Sp.Gr.* | min 1.0 (low up to 0.45) | min 1.0 ( low up to 0.45) |
Temperature* | -50 to 150º C(upto 350º C) | PP: 100º C , PVDF: 150º C |
Hydro Test* | 5 bar (chamber: 60 bar max, Float: 32 bar max.) | Atm. |
Vacuum | Full Vacuum | Full Vacuum |
Least count | 5 mm | 5 mm |
Accuracy | ±1 cms (For Sp.Gr. = 1) | ±1 cms (For Sp.Gr. = 1) |
OPTIONS | ||
Mounting | Side-Top, Side-Bottom | Side-Top, Side-Bottom |
Mounting | Side-Top, Side-Bottom | Side-Top, Side-Bottom |
Switch | Micro, Potential Free contact, 5 A 230VAC SPDT; Die cast Al.-LM6 Enclosure, Weather Proof IP65; (Flameproof IS2148 Gr IIa, IIb or IIc) | Micro, Potential Free contact, 5 A 230VAC SPDT; Die cast Al.-LM6 Enclosure, Weather Proof IP65; (Flameproof IS2148 Gr IIa, IIb or IIc) |
Transmitter | Intrinsically Safe transmitter with 4-20 mA out put (HART®) | Intrinsically Safe transmitter with 4-20 mA out put (HART®) |
Heating Jacket | Grid of SS304 tubes with ½” NPT(F) inlet / outlet | - |
Construction | Metallic | Plastic |
---|---|---|
MOUNTING | Top of the tank and Indication on side of the tank | Top of the tank and Indication on side of the tank |
Indication* | Indicap: Red follower Capsule (Rotocyl) | Indicap: Red follower Capsule (Rotocyl) |
MoC wetted | Stainless Steel 316 (Float & Rope) | PP |
Flanges | CS IS-2062 | PP lined IS-2062 |
Float | 390 Diameter SS316L | 390 Diameter PP(HDPE) |
Rope | 1.6 mm Diameter, multi strand SS316L | 4 mm Diameter, multi strand PP |
Pulleys | C.S.( SS) with SS Bush /Shaft | PP |
Pulley Housing | Die Cast Aluminium - LM6 (SS) | Die Cast Aluminium - LM6 (SS) |
Connecting Pipe | CS | PP lined CS |
Brackets | CS (SS) | CS (SS) |
Gasket, Nut Bolts | Buyer's Scope | Buyer's Scope |
Scale | Aluminium ( SS304, Acrylic, PVC) | Aluminium ( SS304, Acrylic, PVC) |
Paint | Enamel –Phiroza blue, (Epoxy –White) | Enamel –Phiroza blue, (Epoxy –White) |
Scale | Aluminium ( SS304, Acrylic, PVC) | Aluminium ( SS304, Acrylic, PVC) |
Mounting Flange | 25NB (40, 50 NB) ANSI B16.5 # 150(BS 10 : Table D / E / F, DIN: PN 10 or 16.) | 25NB (40, 50 NB) ANSI B16.5 # 150(BS 10 : Table D / E / F, DIN: PN 10 or 16.) |
Range* | 500 to 5000 mm | 500 to 5000 mm |
Temperature* | 50 to 150º C (up to 350º C) | 100º C |
Hydro Test* | Atm | Atm |
Working: A magnetic float (for side mounted magnetic level indicator) or a magnetic tip (for top mounted magnetic level indicator) moves in a chamber on which the sensor is mounted. Magnetically operated reed switches connected to a string of resistors, sense the level signal. The sensor resistance varies in proportion to level. This is converted into 4 to 20 mA current by the Loop Powered Transmitter. LCD display(optional) locally shows the reading
Electrical Sensor: Resistive
Resolution: 1 cm.
Excitation: 2V nom.
Adjustments: Zero (4mA), Full Scale (20mA)
Output: 4...20 mA, 30mA max
Power: 12...30 V (from the loop)
Burden: Less than 750 ohms
Protection: Against loop reversal
Indication: 3 ½ digit LCD (optional)
Intrinsic safety: EEx ia IIC T6. (Cert.No. CMRI/ TC/H512 dt 04 Apr 97)
Mechanical Enclosure: Die Cast Aluminium LM6
Protection Standard: IP 65 IS 2148 Gr IIa II b (Cert. No. CMRI/TC/H293 dt.26 Feb 97)
Cable Entry: 1/2” NPT (F)
Terminals: Screw Type
Working: Latching type magnetically actuated level switch, mounted externally in weather proof (flame proof) enclosure, gives potential free out put, when liquid reaches preset level.
Mechanical Enclosure: Die Cast Aluminium LM6
Protection Standard: Weather proof IP66, Flameproof; IS2148 Gr II a II b ( II C)
Temperature Class: T6
Cable Entry: 1/2” NPT (F)
Adjustment: Stepless over entire range
Type of switch: Snap acting Micro switch
Contact Form: 1 SPDT (2 SPDT)
Contact Rating: 5 A 240 VAC
Differnetial: 12 mm
Working: Magnetically biased reed type epoxy potted (weatherproof) level sensor with integral cable. Mounted externally using strap clamp adjusted steplessly over the non-magnetic chamber, gives potential free out put, when magnetic float inside liquid reaches preset level.
Enclosure: GRP tube & Epoxy potting
Protection Standard: Weather proof IP66
Adjustment: Step less over entire range
Type of switch: Magnetically latching Reed Switch
Contact Form: 1 SPDT (2 SPDT)
Contact Rating: 5 A 240 VAC
Differnetial: 12 mm
Contacts: Hermetically sealed, corrosion free, Ruthenium coated, non moving reeds
Exproof Service: (Armoured cable and Exproof Junction box for hazardous area)